Premises Information

Return to Inspections
NameTANNERS CREEK
Address7405 APRIL MIST TL
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/13/2026
Final Score @ Grade
20
General CommentsNo permit restrictions Note: Verified new pump motor installed on filtration matches HP on motor. Also verified new feature pump was installed and verified with PDSC form. No night swimming Inspection conducted with CPO Luke Fiser and Adam Lund

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Checklist in log book did not include main drain checks. CDI: main drain check slot written in during inspection.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers and skimmer baskets in need of cleaning. CDI: cleaned during inspection. .2518(k) Replace missing weirs. Observed 5 weirs missing. CDI: all weirs replaced during inspection.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed one pole missing body hook due to it being damaged. CDI: pole with body hook was replaced. Observed the other pole with body hook missing the screws. CDI: screws replaced during inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed one out of the two ropes > 50ft. CDI: rope was corrected to 50ft during inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Observed cap/cover missing on vacuum line on pool wall. Vacuum line was turned off in pump room. CDI: cap was provided for vacuum line during inspection.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed no back flow preventer on deck hosebib used to fill pool.