NameMEADOWBROOK - A SUN COMMUNITY
Address9859 SPRING RIDGE LANE
 
City/State/ZIP
CHARLOTTE NC 28215
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/9/2019
Final Score @ Grade
16
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed floating debris in skimmers at beginning of inspection. CDI - Operator removed floating debris during inspection. -4-
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed loose left handrail on ladder nearest pool tables. CDI - Operator tightened ladder during inspection. -2-
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed no sign listing pool address and telephone number at emergency phone. CDI - Operator posted sign with correct phone number and address at emergency phone during inspection. -6-
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Observed hose bib without backflow preventer in equipment room. -2-
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed end of piping from filter backwash extended slightly below the flood plane of the sump. CDI - Operator removed final elbow to restore air gap during inspection. -2-