Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCITISIDE POOL & CABANA
Address4500 EAVES LANE
 
City/State/ZIP
CHARLOTTE NC 28215
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/25/2015
Final Score @ Grade
34
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Maintain records of total alkalinity and cyanuric acid at least weekly. Observed TA/CA recorded only one time in the past month.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed discolored plaster on stairs. Observed one cracked wall tile near 5ft end.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Observed cross hair fittings on pool wall at return lines. Provide correct fitting.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed both throw ropes on ring buoys 53 1/2 ft. Ropes should be 50ft. Corrected during inspection- ropes cut.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate must be self-closing and self-latching unless gate attendent and lifeguard are present. ITS issued. Observed gate not latching.
22 6 Premises: emergency telephone provided No No No Provide visible sign stating location of emergency phone. Observed phone not visible from enclosure and no sign posted. Corrected during inspection- sign posted.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed som leaking pipes in pump room. Observed flow meter not properly functioning.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Mirrors should be shatter proof.