Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Main drain covers do not match PDSC form. PDSC form states main drain covers needs to be AquaStar 1216XXX. Current main drain covers are R12MFXXX. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One weir not installed. .2518(k) Provide functional weirs. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed three endcap( bumper) missing on ladder and hand rails. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed address for emergency phone not transferring to 911. 911 operator stated that system was not showing address or phone number. All info on emergency phone sign posted was correct including address matching with permit. Will follow up within a few days to ensure address is transferring to 911. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Per permit flow meter must be operatable. Observed unreadable flow meter in pump room. During inspection new flow meter was installed and reading below 280GPM per permit. |