Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWOODLANDS
Address1919 SOUTHWIND DRIVE
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/15/2023
Final Score @ Grade
16
General CommentsInspection conducted with CPO Danielle Parker. Verified items from previous inspection have been corrected. *Note* Sign placed at the top of the gate must remain in place to maintain > 45” between horizontals. Pool floor and walls cracked and chipping. Maintain in good condition. Some depth and no diving markers on pool deck cracked. Recommend replacing. Walls in pump room damaged from leaking showers. Maintain in good condition. Recommend providing chemical hazard placard on chemical storage room door. Currently only installed on pump room door. Permit issued No Night Swimming Paper permit will be available on our website https://health.mecknc.gov/envhealth/pools in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No New depth markers on pool wall missing “Feet” or “FT”. .2523(c) Depth markers shall include the word "feet" or symbol "ft". - Corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy with new 55 foot throw rope. .2530(a) US Coast Guard approved ring buoy with 50 foot throw rope at least 1/4 inch in diameter. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Water from shower leaks in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower not functioning. .2526(h) Shower(s) shall be provided.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Lights not working in women’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair.