Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions.
Observed PDSC form showing equalizer change on 02/16/2026. Observed 4 of 5 equalizer covers changed and one 2008 aquastar version.
CDI - Maintenance came from office and changed equalizer covers that did not match to 2017 aquastar and all equalizer covers correct and match PDCS form. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
.2537(14) Keep pool surface and pool floor free of debris.
Observed debris on the pool floor. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed debris in skimmers.
CDI - CPO cleaned skimmers. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521(b) Ladders shall have slip-resistant tread.
Observed ladder missing slip resistant tread.
CDI - CPO replaced tread on ladder. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed ring buoy rope longer than required length.
CDI - CPO shortened rope to required length. |