Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSHARON POINTE APARTMENTS
Address5626 SHARON POINTE RD
 
City/State/ZIP
CHARLOTTE NC 28215
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/23/2026
Final Score @ Grade
18
General CommentsInspection was conducted with PIC Maria and CPOs Francisco and Leo. Permit issued. NO NIGHT SWIMMING.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed all 3 weirs missing. CPO replaced missing weirs with brand new weirs during inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer full of debris. CPO dumped out skimmers.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed ladder missing both endcaps. Replace missing endcaps to prevent damaging pool wall.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed two vacuum lines not plugged. CPO plugged both vacuum lines during inspection.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Observed body hook with telescoping pole. CPO replaced with non-telescoping pole.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed non-weatherproof bag of soda ash stored directly on the floor inside chemical storage room. Ensure all chemicals in non-weatherproof bags are kept stored off of the floor.