Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHUNTERSVILLE FAMILY FITNESS
Address11725 VERHOEFF DRIVE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/8/2025
Final Score @ Grade
20
General CommentsInspection conducted with CPO Kristin Sminchak and George Zimmerman. Pool ~5,500 sq. ft. Will need 8 feet of clear walking space around the pool and 2 sets of body hooks and body tubes. NOTE - Playground is inside the pool area. Some depth and no diving markers on pool deck cracked. Maintain in good condition. Measured pool width at 60 feet. If pool is not lifeguarded, provide 2 US Coast Guard approved ring buoys with attached 50 foot throw ropes at least 1/4” inches in diameter. Pre-permit inspection did not pass. 9) 16) Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No One depth marker on gutter partially missing. .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. - Pre-permit item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One handrail loose. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Some chain link fencing coming apart. 2528(a) Mesh shall not exceed 2.25" square. Some gaps under the chain link fence > 4” inches. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Gaps > 2” under back gate and main gates. .2528(a) Maintain 2" or less under gates. - Pre-permit item. Gate by playground with magnalatch < 54” from the ground. .2528(a) Gate latches shall be 54" in height. - Pre-permit item. Gate by playground not-self-closing. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. - Pre-permit item. Main gates and back gate with openings > 1/2” within 18” of push bar. .2528(a) Gate latches located at less than 54" shall be located on the inside of the gate at least three inches below the top of the gate with no openings greater than 1/2" within 18" of latch mechanism. - Pre-permit item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some chairs too close to pool edge. .2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). - Pre-permit item.
22 6 Premises: emergency telephone provided No No No Incorrect emergency phone number posted. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.