Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHUNTERSVILLE FAMILY FITNESS
Address11725 VERHOEFF DRIVE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/18/2020
Final Score @ Grade
14
General Comments6 - Step located above WAV18WRxxx drain covers cut to approx. 4" above drain cover. Per manufacturer specifications, drain covers requires at least 2" above cover to provide uniform flow. Note - Pool plaster at zero entry appears dark. Not approved by department prior to installation. Provide Light Reflectance Value (LRV). May require repair prior to 2021 operating season. Note - New playground area gate does not meet code requirements. Perimeter fence around playground meets fencing code. Playground area outside of required deck spacing. Permit issued for no night swimming. Permit Restriction - Deck cover located underneath lifeguard stand offset >1/2". Lifeguard stand must remain present over cover at all times pool is operational. Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order. No signature due to COVID-19 restrictions. Jessica Martin present during inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No 6" under fence in some locations. Maintain 4" or less on pools built prior to 2010. All other items noted from previous visit corrected. Meshing added to all three gates to maintain no greater than 1/2" within 18" of push bar. Note - meshing appears rough. Recommend finishing metal edges as to not present a hazard.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck drain near slide rough/rusty. Continue to monitor and repair as needed. At time of inspection, did not appear to present a hazard.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light in chemical storage room not operable. Repair light. Note: Forced ventilation in pump room/chemical storage room. Does not appear to have fresh air intake for ventilation.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Check valve for fill line does not meet .2512. If ever replaced, replace with approved check valve.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib in restrooms. Provide hose bib with backflow prevention device.