NameCOMFORT SUITES
Address7315 SMITH CORNERS BV
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/9/2022
Final Score @ Grade
22
General CommentsPool operating hours are from 10am - 8p therefore night swimming visit is not required. Night swimming is not permitted at this time.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ensure handrails are in good repair. Observed loose handrail. CDI: tightened
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed ~ 8ft of top of metal fence leaning and not secure to wall. Pool was built in 2001. Greater than 50% of the fence is not missing. .2528(a) Gate latches shall be 54" in height. Observed two gates on both sides of the pool with latches < 54”(51 inches) from top of latch to ground. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. CDI: Magna latches were removed and moved up 3 inches to provide 54” in height by maintenance during inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed chairs < 6ft from pool edge. CDI: chairs were moved back to provide 6ft deck clearance
22 6 Premises: emergency telephone provided No No No REPEAT VIOLATION: .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed emergency phone number faded and not clearly visible. CDI: CPO wrote in emergency phone number with marker to ensure clearly visible.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No REPEAT VIOLATION: .2518(g) Keep flow meter operational. Observed flow meter stick. CDI: repaired during inspection.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(i) Water in restrooms shall not exceed 110 F. Observed hot water in restrooms > 110F.