Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameALTA GROVE
Address3212 FLORAL GROVE LN
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/13/2014
Final Score @ Grade
20
General Comments13 - Note: Contrasting color band on steps 1 1/2" to edge. When replastered, assure 1" to edge of steps. Permit will be posted online within 3 days.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed main drain check not recorded daily. Record daily.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladder end cap missing. Provide.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Lighting in pool not operating. Repair lights or no night swimming.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed fans tied to lighting. Provide continuous ventilation in chemical storage.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Observed labeling on recirc pipes faded. Relabel pipes.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap on backwash line to pit. Provide air gap. Cut drain pipe flush to floor to eliminate holding water.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Observed no paper towels in women's. Provide paper towels.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Observed no backflow prevention device on hose bibs - restrooms and showers.