Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameOAKDALE GREEN
Address6100 WHISPERING BROOK COURT
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/27/2024
Final Score @ Grade
14
General CommentsNo night swimming being conducted Inspection conducted with CPO Mikey Cook Permit restrictions: Pump required locked at 3450 RPM due to turnover. Flow meter must remain operable. Minimum flow is 177 gpm.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed PH at 7.0. CDI: corrected to 7.2 - 7.4 during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed some openings under chain link fence > 4”. CDI: fixed by CPO during inspection.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap available in women’s restroom. .2526(k) Provide shatterproof mirrors. Observed no documentation of mirrors in restrooms being shatterproof. .2526(m) Keep restrooms and fixtures clean and in good repair. Observed lights not working in restrooms. Was able to verify all other items in compliance. All other lights at pool working properly. Lights getting repaired before end of week. CPO will send a picture of lights fixed.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed deck hose without back flow preventer. CDI: back flow preventer on site but just needs to be installed.