3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed PH at 7.0. CDI: corrected to 7.2 - 7.4 during inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed some openings under chain link fence > 4”. CDI: fixed by CPO during inspection. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap available in women’s restroom.
.2526(k) Provide shatterproof mirrors. Observed no documentation of mirrors in restrooms being shatterproof.
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed lights not working in restrooms. Was able to verify all other items in compliance. All other lights at pool working properly. Lights getting repaired before end of week. CPO will send a picture of lights fixed. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed deck hose without back flow preventer. CDI: back flow preventer on site but just needs to be installed. |