7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some minor damage to concrete coping at pool stairs and at 5’ end of pool. Minor tile damage near grate fitting in 3’ area. No permit action at this time, however, repair may be needed by next operating season. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Chemical storage room mechanical ventilation not operational. Unable to determine operation of ventilation in pump room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. Pipework for backwash has been re-worked and elbows down into backwash pit - no air gap present. |