| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. Observed chlorine tablets in skimmer basket. Operator advised pool company directed her to add tablets to pool directly in addition to using skimmer. All chlorine added to pool must be through chlorinator. Do not add chlorine to pool unless “shocking” and pool is closed for swimming. *permit item |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some minor damage to concrete coping at pool stairs and at 5’ end of pool. Minor tile damage near grate fitting in 3’ area. No permit action at this time, however, repair may be needed by next operating season. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Surface skimmers shall be installed per manufacturer's instructions. Weir in one skimmer installed improperly blocking water flow subsequently detached. Repair. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. Multiple depth markers on pool walls significantly faded. *Permit item
.2523(d) No Diving markers shall be provided in all areas of the pool less than five feet deep. Distances between multiple no diving tiles on pool deck exceed 25’ *Permit item |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope greater than required 29’. Corrected to 29’ during inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Three windows leading from clubhouse directly onto pool deck open fully. Windows that open directly onto pool deck must be limited to open no more than 4”. *Permit item |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Flow meter not operational. Permit condition exists requiring operable flow meter due to pump change out and installation of new variable speed pump. Flow meter must remain operational. *permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Chemical storage room mechanical ventilation not operational. Unable to determine operation of ventilation in pump room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. Pipework for backwash has been re-worked and elbows down into backwash pit - no air gap present. |