Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHOLLY RIDGE
Address8155 CHRISTMAS COURT
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/1/2026
Final Score @ Grade
18
General CommentsNo night swimming No permit restrictions Inspection completed with Chris Andrews CPO

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed 2 weirs missing. CDI: weirs were replaced.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed fence in some areas < 48” due to landscaping and pine straws. CDI: pine straws were removed and fence corrected to 48”.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Observed minor cracking in pool deck. No trip hazards observed. Repair as needed.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. Observed lights not working inside pump and chemical room. Operator stated that he is working with HOA to get lights repaired.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap in women’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair. Observed lights not working inside restrooms.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed no backflow preventer on hosebib on deck. CDI: back flow preventer was provided by operator.