5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
REPEAT VIOLATION: Main drain checks not recorded daily. Record main drains daily. CPO stated that he checked them but just forgot to check the box.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
.2537(14) Keep pool surface and pool floor free of debris. Observed debris in pool from pollen. CDI: pool cleaned during inspection. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
REPEAT VIOLATION:
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris observed in some baskets. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope > 50ft. CDI: rope shortened to 50ft during inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
REPEAT VIOLATION:
.2528(b) Horizontals shall not be located less than 45" in height. HVAC unit outside fence located near pump room provides foothold at 37” from ground and 35” to top of fence. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
REPEAT VIOLATION:
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Pool furniture within 6’ of edge of pool. CDI: Furniture moved to provide 6’ clearance.
.2537(2) Decks shall be kept in good repair. Observed some areas on deck with small cracks/gaps. Observed some no diving markers peeling up on deck. CPO glued markers back down. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
REPEAT VIOLATION:
.2518(g) Keep flow meter operational. Flow meter stuck. Repaired by CPO during inspection. |