Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePRINCETON AT SOUTH HAMPTON
Address16800 COMMONS CREEK DR
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/29/2022
Final Score @ Grade
34
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Pool pH measured 6.8. CDI - Operator corrected pH to 7.3 during inspection.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Pool floor and walls have debris and buildup on them and need to be cleaned.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris in skimmer baskets. Clean.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Step ladder is loose. Secure ladder to manufacturer’s instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope length was 41 feet. CDI - Operator cut rope to 30 feet during inspection.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Emergency phone had ability to be called back, but the ringer was not working. CDI - Operator replaced emergency phone with new one with audible ring.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Flow meter not operating. Replace or repair flow meter.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Pipes and valves not labeled in pump room.