NamePROSPERITY VILLAGE
Address12400 JESSICA PL
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/26/2024
Final Score @ Grade
14
General CommentsThis pool is not permitted for night swimming. Pool is listed to have 8 returns but during inspection only 7 were observed. Pool is able to meet turnover rate calculation. The following items were field verified: Pump Hayward SP32950VSP Piping 2” main drain, skimmer and return (where it comes up and goes into the pump room floor) Flow meter Between 78 and 98gpm (Observed flow during inspection was 97) Filter TR100HD Main Drains Aquastar A10RCFRxxx Equalizers Aquastar 6HPHAxxx Skimmers 3 Permit issued.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed one inch separation of coping from tile on pool wall creating a gap. Repair. A follow-up inspection will be conducted to ensure this is repaired.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed buoy rope measuring over 39 ft. Rope is required to be 39 ft based on 1.5 times width of pool. CDI: Pool operator adjusted length for compliance.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. Observed light not operating in pump room. Pool operator states that it is a fixture issue and that it will be getting repaired. Repair to ensure sufficient lighting. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.observed no cross ventilation in pump room. One grate present on door.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed backwash pipe below rim of drain pit. Correct to provide an air gap.