3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Observed ph at 7.9. CDI - operator, Jennifer Mullins, adjusted ph to 7.5 while on-site. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture less than 6 ft. from edge of pool. CDI, operator relocated furniture to provide required clearance. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed no lifeguard on duty sign posted with lettering measuring less than 4". CDI, operator provided signage during inspection that meets requirements. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed bag of chemical stored on ground.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Observed no backflow prevention device on hose bib in restrooms or near equipment room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2626(l) Provide toilet paper and dispensers in restrooms. Observed no toilet tissue available in men's and women's restroom. |