Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSTEPHENS GROVE
Address6101 STEPHENS GROVE LN
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/21/2020
Final Score @ Grade
12
General CommentsInspection conducted with Jacob Wilks and Landon Wiese. Due to COVID-19 precautions, inspection was not signed by the operator. Valve handle missing for vacuum line. Provide functional valves with handles. Backstroke flag poles not installed. Ensure that poles are installed or deck anchors are covered prior to opening the pool. Bonding wire runs across the pump room floor. Recommend routing under door threshold to eliminate trip hazard. Some lights burned out in pump room. Recommend replacing non-functioning bulbs. Verified PDSC information. Permit issued. No night swimming. “Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer not functioning, two with very little flow. Adjust trimmer valves, clean lines, etc. to ensure that skimmers are properly functioning prior to opening the pool. .2518(k) The flow-through rate through any one recessed automatic surface skimmer shall be between 20 gallons per minute and the maximum flow the skimmer is certified for under NSF Standard Number 50.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not properly installed to measure true flow. .2518(g) Install flow meter on return line per manufacturer instructions.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Most piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. - Corrected.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash line extends into backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.