8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed one skimmer without weir. Replaced. Some algae in skimmers at 5 ft. Clean. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed one ladder rung missing slip resistant tread. Provide tread. Observed ladder 8" between rail and wall. Maintain between 3" and 6". |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Observed 3 pool lights burnt out. Replace. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Observed no air gap at backwash line to pit. Provide air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Observed damaged faucet handle in men's. Repair. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Observed hose bib in women's without backflow prevention. Provide backflow prevention device. |