| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 7.0. Corrected to 7.2 during inspection. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some algea on pool steps and around equalizer line covers. Keep clean. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One weir missing from skimmer. Replace weir. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
28 to 30 ft between wall depth markers at steps on either side. Install depth markers every 25 ft or less on pool walls. Intent to Suspend issued. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Two end caps missing from ladders. Ladder >6 " from pool wall. Maintain end caps and provide ladder between 3" and 6" from handrail to wall. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
More than half of returns missing fittings. Replace where needed. Intent to Suspend issued. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Pool greater than 3000 sq ft. One ring buoy without rope. Corrected during inspection. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Minor damage to plastic decking at 4 ft. Keep in good repair. Eliminate hazard. Intent to Suspend issued.Fill spout on deck left open. Provide plug to eliminate hazard. Intent to Suspend issued. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
No dialing instructions at emergency phone. Corrected during inspection. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Light and fan not operable in chemical storage room. Provide. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Drain in backwash pit not cut flush so standing water. Cut pipe flush to bottom of pit. |