6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Equalizer line cover installed on one vacuum port, other vacuum port missing plug. Install plugs on vacuum ports when not in use. Corrected by operator. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One equalizer line cover missing. Install A112 approved equalizer line cover. Corrected by operator. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Handrail loose. Maintain secure and in good condition. Tightened by operator. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Missing one inlet fitting. Corrected by operator. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
HVAC at fence < 45" high. Maintain fence at least 48" high w/ no footholds < 45".
Windows to clubhouse are able to open > 4". Ensure that windows cannot open > 4" onto pool deck. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Underwater light loose. Maintain securely attached to the wall. Corrected by operator.
Glass lighting on pool deck. Install safety backing to glass or replace with shatterproof materials. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water > 110F. Maintain at 110F or less. |