Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVALON APARTMENTS, THE
Address6000 REGAL ESTATES LN
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/12/2023
Final Score @ Grade
20
General CommentsPermit denied. No night swimming. Once all 4 and 6 pt demerit items are in compliance, please call 980-314-1620 to remit the $100 re-inspection fee. Then call Sr. EHS A. Hall to schedule a re-inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope for ring buoy longer than 39ft. CDI: Rope shortened to required length.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed right side door to lobby not self-closing, self-latching. CDI: Door made self-closing, self-latching during inspection. Observed rear pedestrian access gate padlocked with no latch.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Observed Kings III phone box on deck unable to dial out to 911. When activated. Phone box only repeats recording stating “You have activated this emergency telephone connecting you to an emergency dispatch center. Please stay on the line a live emergency operator is connecting now.” .2530(f) Emergency phone shall remain operable. Observed phone unable to be called back.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed vent fan not working. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Observed vent fan not working.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at the backwash pit.