Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBRYCE NORTH CHARLOTTE
Address4101 DOUBLE CREEK CROSSING DR
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/23/2026
Final Score @ Grade
20
General CommentsFlow meter operable. Flow was 70 gpm. No night swimming permitted. Permit issued.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Debris in pool. Vacuum pool
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Replace missing weir.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Ladder is loose. Secure ladder according to manufacturer’s instructions
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope was 54 feet. CDI - Operator cut it to 50 foot length.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Water around pump. Repair leak.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. No air gap between pipe outlet and backwash pit.