Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBRYCE NORTH CHARLOTTE
Address4101 DOUBLE CREEK CROSSING DR
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/23/2023
Final Score @ Grade
34
General CommentsPermit Restriction: 1) Left double door to pool must remain locked at all times so that door remains self-closing, self-latching. Permit issued for no night swimming. Intent to Suspend issued for the following: .2535 - maintain daily record keeping for main drain checks and weekly records for total alkalinity and cyanuric acid .2518 - repair pressure gauge on left filter .2523 - install deck depth marker at 3 ft. .2518 - provide spare pump basket for pump Note - Pump grounding wire was not attached during the inspection. Operator attached. Picture sent to Code Enforcement and will follow-up. Note: Some air still being introduced to pool. Continue to monitor. May indicate a leak.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No main drain checks. Record main drain checks daily. No cyanuric acid and total alkalinity checks recorded. Operator stated taking weekly. Record weekly. Intent to Suspend issued for record keeping.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some algae around ladder rungs and equalizer lines. Continue to monitor. Treat as needed.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Missing deck depth marker above 3 ft. at main step entry into pool. Located on wall. Provide 3 ft. depth marker. Intent to Suspend issued. >25 ft. between No Diving markers from right side of main entry step to next no diving on left side. Also for right side step entry. 25 ft. as the crow flies. Provide Deck NO Diving markers at 25 ft apart or less prior to 2024 operating season.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No End caps missing off ladders. Provide end caps.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Both ring buoy ropes too long. Cut to 50 ft. during the inspection. Grab rope on one ring buoy degrading. Replaced ring buoy during the inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No >1/2" meshing on gates. Openings shall not exceed 1/2". Repair prior to 2024 operating permit. Pool fence less than 48" in height in some areas due to landscape and <45" between horizontals. Pillar tie into fence where fence not 48" in height. Pool built pre-2010.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool >1600 sq. ft. Some deck chairs too close to pool edge. 2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). Some deck damage where deck is popping. No offsets >1/2". May require repair in the future. Continue to monitor.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Small leak at multiport of right filter. Repair leak. Pressure gauge not working on left filter. Repair. Intent to Suspend issued. No spare pump basket for pump. Provide spare pump basket. Intent to Suspend issued.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No backflow prevention device on hose bib in pump room. Hose bib prior to check valve. Provide backflow prevention device.