| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No checks on weekends. No recent Main Drain, Cyanuric Acid or Total Alkalinity checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Pre-permit item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Pool floor dirty. Lots of leaves floating on pool surface on far side of the pool. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some skimmer baskets full. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Pre-permit item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder missing non-slip tread.2521(b) Ladders shall have slip-resistant tread.
Ladders loose, some missing escutcheon plates and end caps. .2521 Install ladders per manufacturer instructions.
Handrail loose. .2521 handrails per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Body hook not present. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Corrected.
Ring buoy damaged. Throw rope heavily knotted.
.2530(a) Provide USCG approved ring buoy with 50 foot throw rope at least 1/4 inch in diameter. - Pre-permit item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Large springs on gates < 45” high. .2528(b) Horizontals shall not be located less than 45" in height. - Pre-permit item.
Pre-2010 fence with sections < 48” high. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
Pre-2010 fence with some gaps > 4” under the fence. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool >1600 sq. ft. Some deck chairs too close to pool edge. 2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone at the back of the grill area, not visible from the pool deck. .2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. - Pre-permit item.
Signage posted away from emergency phone. Incorrect phone number posted. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pre-permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not installed per manufacturer’s instructions. .2518(g) Install flow meter on return line per manufacturer instructions such that it can read with +/- 10% accuracy. - Pre-permit item. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Toilet paper dispensers empty in some stalls. .2526(l) Provide toilet paper and dispensers in restrooms. |