15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Rope for both ring buoy’s measured over 50 feet in length. Operator cut both ropes to measure 50 feet in length. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a)(2) Openings in the barrier shall not allow passage of a four-inch diameter sphere and shall provide no external handholds or footholds. Five inch footholds were observed outside of fencing near front gate. Operator placed barriers over footholds to prevent entry over fence. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. A 1 inch crack through concrete where pool deck meets pool was observed on near side corner side of pool. Operator placed pool putty in the crack to remove offset. |