11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed loose pool step ladder and loose handrail. / TIGHTEN STEP LADDER AND HANDRAIL |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed ring bouy rope measuring greater than required length of 24ft. / CORRECTED TO 24FT |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed pool deck furniture within 6ft of pool. / FURNITURE STACKED AGAINST FENCE TO GIVE 6FT OF CLEARANCE AROUND POOL |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Observed EMERGENCY PHONE to work correctly but the 911 Operator informed me that the number shows up as a truncated number that goes directly to the front desk and not to the pool phone. / FOLLOW UP REQUIRED WITHIN 3 DAYS TO ENSURE FACILITY HAS SECURED A DIRECT LINE FOR THE POOL EMERGENCY PHONE. CALL KATIE WILSON @ 704-309-5494 ONCE NUMBER IS FUNCTIONAL. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed the bobbit in the flow meter to be stuck and not moving. / PROVIDE A FLOW METER WITH FUNCTIONING BOBBIT |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed equipment room floor to be wet. / Keep Equipment & Chemical room floors dry |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Observed backwash pipe to not have a true air gap. / ELEVATE PIPE TO PROVIDE TRUE AIR GAP |