Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTRELLIS-WEST CHARLOTTE
Address2770 YORKMONT RD
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/29/2025
Final Score @ Grade
14
General CommentsProperty under renovation at time of inspection. If restrooms are remodeled they must meet full compliance of pool code. Submit in-field plan review to Health Dept (include slip resistant flooring specs, floor drains, hose bib with anti siphon device and shatterproof mirrors, no glass) No Night Swimming. Pool not heated Inspection with Curtis Baker Issued permit sticker.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One loose ladder. Keep tight and in good repair.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoys on deck not US Coast Guard approved and rope too long at time of inspection. .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator attached 27 ft rope to approved buoy and replaced. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate not latching at front. Back fencing area, replaced with grills, 37” in height. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). .2537(b) All gates and doors shall be self-closing, self-latching. Operator adjusted gate to self-close, self-latch. Operator added plywood to grill area to increase height of barrier to 48” and eliminate horizontals. If further changes are made, ensure code is met. Corrected.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Restrooms out of order. .2526(m) Keep restrooms and fixtures clean and in good repair.