Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTHORNBERRY APARTMENTS
Address9920 BRICKLEBERRY LN
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 8/17/2026
Final Score @ Grade
12
General CommentsInspection conducted with CPO Jon Guyton. Follow up from previous inspections. Note: New Pentair WhisperfloXF VS 022035 pump installed. Verified all in-field plan review items on previous inspections. New permit condition that flow meter remains operational and read between 163 and 196 GPM for minimum turnover and restriction of the filters. - Verified at 172 GPM at 3450 RPM using new Aquastar FM30 flow meter. Blue-white flow meter installed between two elbows. Handrail not anchored to the pool deck. Pavers around handrail broken. Prior to 2027 permit being issued, will need to properly install the handrail. Ensure it is securely installed into deck anchors that are properly bonded to the pool. May need an electrical permit and passing electrical inspection from Mecklenburg County Code Enforcement depending on scope of repairs. Permit issued with following conditions: No Night Swimming Flow meter must remain operational and be between 163 and 196 GPM for minimum turnover and restriction of the filters. Paper permit will be available on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder > 6” from pool wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall to ladder rung. Handrail not secure, easy to pull out of the pool deck. .2521 Install handrails per manufacturer instructions.- Will need to repair prior to 2027 permit being issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door to office not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items stored beside pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Bags of dry chemicals on the floor in the pump room. .2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No New piping not labeled. .2518(d) Piping and valves shall be labeled with color codes with a legend or labels.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink. No toilet paper on toilet paper holders in most of the stalls. .2526(l) Provide toilet paper and dispensers in restrooms. 3 lights burned out in men’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair.