9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
One set of depth markers on pool wall > 25 feet apart. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Corrected by operator.
Newly added depth markers not denoted in FT or FEET. .2523(c) Depth markers shall include the word "feet" or symbol "ft". Corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder crooked. .2521 Install ladders per manufacturer instructions. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Some fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Some fence sections with gaps > 4" through the fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Spare pump basket not observed. .2518(e) Provide a spare basket for pump.
Flow meter stuck. .2518(g) Keep flow meter operational. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Light not working in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restroom 126.3F. .2526(i) Water in restrooms shall not exceed 110 F. |