Inspection Date 4/28/2026
Final Score @ Grade
30
General CommentsFlow to remain between 99 - 119 out meet turnover and flow restriction of the drain covers. Suction hazard. No Night Swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. pH at 6.8. Corrected to 7.2 during inspection.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed slight debris present in skimmers. Clean as needed. .2518(k) Replace missing weirs. Observed 1 weir missing. Replace as needed.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed ladder and handrail loose. Tighten.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed ring buoy in bad repair. PIC replaced with a new USCG approved one.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed fill spout missing and a gap of 1” located in the deck flooring. PIC placed plug in hole.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed “NO LIFEGUARD ON DUTY” sign without the “ WARNING “ portion. PIC made an additional sign that states “WARNING” in 5” bold lettering. PIC will purchase a professional sign prior to pool season.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. Observed lights not in operation. Repair.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed filter discharged through an air break only. Trim pipe so discharge is through air gap.