| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Gap between wall and equalizer line cover. .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. - Pre-permit item. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Most depth markers on pool deck missing “FEET” or “FT” or heavily faded. .2523(c) Depth markers shall include the word "feet" or symbol "ft". - Pre-permit item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladders missing slip-resistant tread. .2521(b) Ladders shall have slip-resistant tread. |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Contrasting tiles more than 1” from step edge and more than 1” away from pool wall. .2521(b) Provide at least 2"x 2" tile for contrasting color band within 1" of adjacent tiles and edge of the entire length of stair tread. - Pre-permit item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
New ring buoy with 60 foot throw rope. .2530(a) Provide USCG approved ring buoy with attached 42 foot throw rope at least 1/4 inch in diameter. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence with openings > 4” through the fence at retaining wall. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Hole in deck where fill spout goes. Ensure any plug provided is flush to pool deck. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Pre-permit item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Light out in pump room. .2533(b) Provide sufficient lighting in pump room.
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Light out in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
Inadequate ventilation in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No toilet paper dispenser in men’s or women’s restrooms. .2526(l) Provide toilet paper and dispensers in restrooms. |