NameAUTUMN PARK APARTMENTS
Address8500 DIGITAL DRIVE
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/9/2021
Final Score @ Grade
44
General CommentsInspection conducted with Derek Hutchins. Due to COVID-19 precautions, inspection was not signed by the operator. Recommend replacing flow meter, most of the numbers worn off. Both showers not functioning. Recommend providing functional showers prior to opening the pool. Light switch in chemical storage room hanging out of the wall, wires exposed. Have electrician properly secure switch in the box and install a switch plate. Posted pool hours are 10 AM - 10 PM. Change hours to reflect that pool closes at dusk or schedule pool lighting inspection to verify there is sufficient lighting to allow for night swimming. Exposed wiring on 3HP replacement pump motor. Motor not bonded to the pool. Have a licensed electrician properly wire the motor and connect bonding wire. Will need an electrical permit and passing inspection from Code Enforcement prior to scheduling reinspection. Inspection did not pass. A $100 reinspection fee will need to be paid prior to scheduling a follow up inspection. This can be done by calling our main office (980) 314-1620 and paying with a credit card. Permit Denied Pump motor electrical inspection 5) 6) 7) 8) 12) 15) 16) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records not being kept yet. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No PDSC does not match what is installed. Observed 8 HP covers, form states 6HPA covers are installed. Pump is actually Pentair XFE-12 3 HP pump .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Pre-permit item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool floor dirty. Algae growing in the corners. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing 3 of 5 skimmers. .2518(k) Replace missing weirs. - Pre-permit item Far skimmers with little to no flow, some have leaves sitting in the suction lines. Recommend cleaning the lines out .2518(k) The flow-through rate for each skimmer shall be between 20 gallons per minute and the maximum flow the skimmer is certified for under NSF Standard Number 50. - Pre-permit item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Handrails loose. .2521 Install handrails per manufacturer instructions.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Some inlet fittings chipped or damaged. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook in the pump room, no pole attached. .2530(a) Provide body hook on 12 foot non-telescoping, non-adjustable, and non-collapsible pole. - Pre-permit item. New USCG approved ring buoy and 60 foot throw rope. .2530(a) Provide USCG approved ring buoy with 50 ft throw rope. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Most gates chained shut, unable to test. Magnetic closure for main gate not working. Ensure electronic gates operate on a battery backup. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Pre-permit item. Door from fitness center tied to a motion sensor, push to exit button disabled. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Vacuum cap missing. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in pump room or chemical storage room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Light not working in the pump room. .2533(b) Provide sufficient lighting in pump room. Chemicals and other items stored by the pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No toilet paper in women's restroom. .2526(l) Provide toilet paper on dispensers in restrooms.