| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
PDSC form shows Aquastar 12MF 101 maindrain covers, observed Aquastar 1216 xxx main drain covers. Need to correct PDSC from - Permit on hold till PDSC form received and approved. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Observed one 3 FT depth marker missing from pool wall at stairs making more than 25ft between depth markers. Corrected during inspection, PO installed a depth marker tile at stairs. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed stair handrails to be loose, needing tightening. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Observed pool light separating from wall leaving 1.5"-2" gap from wall. Have pool light re-fastened to wall to eliminate gap to 1/2" or less. - Permit on hold till proof of correction. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed 61 ft buoy rope. PO corrected rope to required 50 ft. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Pool safety sign posted does not meet rules, observed incorrect wording and letter size 1/2", needs exact wording and 1" min. size letters. - PO made and posted a correct pool safety sign. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemical room exhaust fan needs to be directly connected for continuous use. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Restroom mirrors not shatterproof