Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Operator checking Calcium Hardness, not testing Cyanuric Acid. Check Cyanuric Acid at least weekly. Operator tested CYA at 55ppm. Left copy of state pool log sheet for operator to use. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Equalizer line cover unseated from backing plate. Install A112 approved covers per manufacturer's instructions. Corrected by operator. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Inlets by ladder and at breakpoint nearest the hotel are not functioning. Recommend checking that the lines are not blocked. |