11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One of the ladders not installed. .2521(a) Steps or ladders shall be provided every 75 ft along the shallow area perimeter. .2521 Install ladders per manufacturer instructions. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gate for Tiki Bar not self-closing or self-latching. .2528(a) Gates other than pedestrian access gates shall have a self-latching device. Latch corrected by operator, gate will remain locked when not in use. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Incorrect phone number posted for emergency phone. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Corrected by operator. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Pool recently replastered, eyeball fittings installed on vacuum lines. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Corrected by operator. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Filters leaking. .2533(d) Pump room floor shall be kept dry and free of standing water.
Chemical storage room used for general storage. Store only pool chemicals in the chemical storage room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash line extends into backwash pit. .2513(b) Filter backwash shall be discharged through an air gap. |