Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHIGHLAND CREEK SWIM CLUB-CLARKE CREEK
Address6000 CLARKE CREEK PARKWAY
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/17/2024
Final Score @ Grade
8
General CommentsNO NIGHT SWIMMING. Field verified the following: New Pump Jandy JCP Series, JCP05-3AT-S, 5 hp Permit Restriction - Flow meter must remain operable. VFD must remain set so that flow maintained at 210 gpm to 220 gpm to meet turnover and flow restriction of number of returns. Blue White Flow meter operational Main Drain Skimmer and Return line all 4” line going into the pump room floor. (2) Aquastar VGBA-2017 1216xxx drain covers. (3) Pentair TR140C Filters (11) Returns either on floor or wall (double check this one since it’s a permit restriction). (7) skimmers with EQ lines plugged

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Provide at least one handrail on steps. Handrail on ADA ramp needs to be secured. Add escutcheons at base.
22 6 Premises: emergency telephone provided No No No .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. 911 connection and verification was made today, however significant static was on the line with 911. CDI- CPO changed to new phone.