Inspection Date 5/17/2024
Final Score @ Grade
18
General CommentsInspection conducted with operator Luke Fiser. Permit issued. No night swimming. Note: damage to concrete on deck in deep end of pool require repair prior to 2025 permit issuance. Observed significant cracking on interior of skimmer in 3’ end of pool - monitor to ensure skimmer remains in good repair.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer baskets. Baskets being cleaned during inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture within 6’ of pool. Corrected. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed cracked/damaged deck concrete in corners at edge of pool in 5’ end. Offsets approaching or at 1/2”. Requires repair prior 2025 permitting.
22 6 Premises: emergency telephone provided No No No .2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Emergency phone located inside of pool room not visible to pool deck - signage with location of pool phone obstructed from view by furniture. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Keep clear walkway around equipment - storage in pump room obstructing access to pipework and equipment. Chemicals stored in pump room. Pool built 1999.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed hose bib on pool deck with no vacuum breaker.