| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 7.0. Maintain at 7.2 to 7.8. Permit denied. Permit item. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
PDSC form submitted and disapproved. Incorrect information on PDSC form. Submit PDSC form. Viewed (2) Aquastar VGBA-2017 1216xxx drain covers. 4 skimmers with (4) 6HPHAxxx VGB-2008 equalizer line covers. Permit denied. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some staining on pool floor. Keep pool free of staining. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Two of four skimmers with low flow. Skimmers shall be operable. Ensure uniform flow through skimmers. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy and grab rope degrading. Replace with USCG approved ring buoy and 45 ft. rope. Permit denied. Permit item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some damage to pool deck around deep end skimmer. Repair. Permit item. Permit denied. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Chemical feeder pump not interlocked to pool pump. Have to unplug from wall to make inoperable. Permit restriction from previous year where both needed to be interlocked. Permit denied. Permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
No spare pump basket for pump. Provide spare pump basket. Permit denied. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No light in chemical storage room. Provide light.
Provide 3 ft. clearance around all equipment. Original construction.
Outside chemical storage area with walls that do not go to ceiling. Original construction. .2534(1) Chemical storage room shall be weatherproof with a minimum ceiling height of 7 ft.
Pump room floor wet and floor drain cover missing. Keep dry and replace grate on floor drain. Floor wet due to leak at old chemical feed line. Repair leak. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
One sink not operable in women's. Keep sinks operable. |
|
32
|
2
|
Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean |
No |
No
|
No |
Damage around floor drain in one shower of women's. Recaulk/seal and keep in good repair. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib or floor drain in pump room. Original construction. Provide hose bib and floor drain. |