Select your filters and click the Search button to search for data, or click Clear to clear all filters
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
Premises Information
Return to Inspections
Name
HARBORSIDE TOWNHOMES
Address
18435 HARBORSIDE DR.
City/State/ZIP
CORNELIUS
NC
28031
Premise Type
50 - Seasonal Swimming Pool
County
Mecklenburg
Inspection Date
4/30/2021
Final Score @ Grade
4
General Comments
Per Katie PERMIT RESTRICTION - PUMP IS PERMANENTLY WIRED AT 2500 RPM DUE TO FLOW RESTRICTIONS OF THE FILTER. PRESSURE GAUGES MUST REMAIN - 6 PSI AND -7 HG. FLOW METER MUST REMAIN OPERABLE NOT TO EXCEED 92 GPM DUE TO FILTER. He has added pressure gauges that you will need to verify after they backwash the filter. Please ask them to backwash first. Also flow meter should not exceed 92 gpm. Things to verify 1) Jandy VSFHP270AUT, 2.7 thp pump 2) All piping – 2” 3) (2) Aquastar A10RCFRxxx drain covers 4) (5) Aquastar 6HPHAxxx equalizer line covers 5) (1) TR100c filter 6) 6 returns 7) Permit restrictions listed above
Violations
CDI=Corrected During Inspection
R=Repeat Violation
VR=Verification Required
Violation Item
Demerits
Violation Description
CDI
R
VR
Comments
24
4
Equipment room: approved pump, filter, and flow meter operating properly
No
No
No
no air gap for backwash