NameMELROSE OWNERS ASSOCIATION
Address4045 MELROSE CLUB DRIVE
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/26/2023
Final Score @ Grade
28
General CommentsNOTE: Flow meter read and verify in the field at 85 GPM. Flow meter is not meeting the turnover . If clarity become an issue or occur, the pump may be required to change. The pool #500814 permit is denied due to all the violations noted on the inspection sheets. All items have to be fixed prior to pre-permit. Once all items corrected. Please call 980-314-1620 to pay $100 fee for re-inspection for permit. Then contact Ponpasert 704-617-9777 to schedule an appointment for permit inspection. This pool does not have a permit to operate at this time. The pool must remain close until permit issue.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH= 8.2. Corrected during the inspection at 7.8.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Ladders shall have slip-resistant tread. Observed missing non-slip pad on the third step ladder. Need replacement.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed damaged ring buoy. Corrected during inspection, new ring buoy was replace and rope attached 39’.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed one of two magnet gates is not working properly. It does not latch promptly. Need repair and ensure all gates are self closed or self latched.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed cracked on one end of a deck toward fencing. Need repair and ensure that will not be a trip hazards.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Observed pool phone is not working. Need repair or replace and remain operable.