Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePARKSIDE @ SOUTH TRYON
Address605 CANDLER LN.
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/16/2026
Final Score @ Grade
14
General CommentsInspection accompanied by CPO, David Hunt. Permit issued. Field verification conducted: 3” line 140GPM, 1.5” 25GPM. 5% accurate Blue White F-300 flow meter observed at 3” return line. Not approved for night swimming. CPO must replace flow meter on 1.5” line within two weeks. Permit conditions: Requires 5% flow meter for 2026 on 3" return line. Flow meters must remain operable - required on both 3" and 1.5" return lines. Flow on 3" return shall not exceed 150 gpm due to drain cover flow restriction. Suction Hazard. Flow on 1.5” return line shall not exceed 40 gpm due to pipe flow restriction.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Install skimmer per manufacturer specifications and eliminate equalizer line plugs or plug per State requirements. Observed 2 of 5 equalizer lines with plug inserted backwards. Re-install equalizer plugs properly at earliest opportunity. Ensure lines are cleared of water before plugging to prevent damage.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed damaged interior pool lighting coming away from side wall nearest to pump room. Corrected- CPO screws light fixture to pool wall properly.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter buoy at 1.5” line required cap loosening/re-tightening to become responsive and register flow. Field verification was successful but CPO is advised to replace the flow meter so it remains in good repair within 2 weeks. CPO to follow up after Memorial Day.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed glass casing around light bulbs above restroom hand sinks. Remove or replace with shatterproof bulb casing.