Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOMFORT SUITES-UNCC
Address7735 UNIVERSITY CITY BV
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 9/25/2024
Final Score @ Grade
36
General CommentsRobin Vansickle present during the inspection. Acting CPO. CPO must make daily site visits for pool to be open. No staff onsite with CPO certification. Do not open pool to public of daily site visit does not occur. Permit issued for no night swimming. All permit items from previous site visit corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid lowered to 100 ppm from previous site visit. Continue to lower. CYA at max level permitted.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some staining on pool floor. Keep floor at >50% light reflectance.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Minor damage to skimmer basket closest to the steps. Replace skimmer basket.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No One no diving marker not attached. Reattached during the site visit. One cracked depth marker at 3 ft. Still secure. Monitor and replace if not secure.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy grab rope degraded. New ring buoy was provided during the site visit.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on chlorinator. Original construction. Install with flow meter per NSF approval if replaced. Small leak at chlorinator. Repair leak.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not installed per mfg. instructions. Old style flow meter requires 10xpipe diameter on inlet and 4xpipe diameter on outlet. If replaced, install per mfg. instructions. No permit restrictions or flow restrictions. No spare pump basket for pump. Provide spare basket.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet due to leak at chlorinator. Keep dry.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >116 F. Maintain at 110 F or below. One stall locked in women's restroom. Toilet in need of cleaning. Keep fixtures accessible and clean.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib in restrooms. Original construction. Provide hose bib in restrooms.