| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recording calcium hardness instead of cyanuric acid. Check daily Cl, pH, Main Drains and pool maintenance activities. Check at least weekly Total Alkalinity and Cyanuric Acid. Operator tested CYA at 40ppm. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Weir not installed in far weir. Install functional weirs.
Water level above skimmers. Maintain proper water level for functional skimmers. Corrected by operator. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
>75 feet between steps and ladder. Provide ladders and steps no more than 75 feet apart. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy damaged. Replaced by operator. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Back gate not self-latching, < 48" high. Corrected by operator. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Covered canopy too close to the pool. Maintain at least 6 feet clear walkway around the pool. Corrected by operator. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Provide spare pump basket. Corrected by operator. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Leak at pump. Fix leak.
Dry chemicals stored on the ground in the pump room. Store on a shelf, pallet or in a bucket. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Back wash a direct connection. Provide air gap for backwash. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Provide signage directing bathers to shower before entering the pool. |