3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH corrected to 7.2 during the inspection |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
eliminate footholds-need to be > 45" from top of fence; clubhouse door corrected to be self-closing and self-latching; cranks were removed from clubhouse windows to prevent them from opening > 4" |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
natural cross or continuous forced ventilation required |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
2" air gap required on backwash line |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
mirrors to be of shatterproof construction |