8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Weir stuck. Corrected by operator.
Skimmers furthest from the pump room barely pull, while skimmers closest to the pump room pull really well. Recommend installing sliding skimmer tabs in the skimmers to throttle the flow for skimmers closest to the pump room to get even flow at all skimmers. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One inlet fitting clogged. Provide functional inlet fittings. Corrected by operator. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Both throw ropes 56 feet long. Corrected by operator to 50 feet. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gap under fence > 4". Maintain fence with no gaps > 4".
Windows that open onto pool deck open all the way. Ensure that windows do not open more than 4". Can superglue the window stops open so that windows cannot open more than 4". |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Store chemicals in chemical storage room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Faucet in men's restroom loose. Maintain in good condition.
Some of the stalls in women's restroom out of toilet paper. Provide toilet paper on a toilet paper holder in all of the stalls. |