Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSLEEP INN
Address9900 MATTHEWS PARK DR
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/9/2019
Final Score @ Grade
22
General CommentsThrow rope for ring buoy starting to show signs of deterioration for sun exposure. Rope must be replaced before beginning of next season. No night swimming allowed until EHS can verify lighting requirements.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Install skimmer per manufacturer specifications and eliminate equalizer line plugs or plug per State requirements. One equalizer line plugged inside skimmer. CDI - Plug removed during the inspection.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. One loose handrail. Tighten.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. One gate not self-closing; stops before contacting latch. CDI - Gate was closed, locked, and screwed to the fence to permanently close.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Call back number posted on sign is incorrect. Number corrected to 704-845-8004.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Flow meter bobber stuck. CDI - Maintenance repaired during the inspection.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. End of discharge pipe extends below top of flood rim into discharge pit.