3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0 -CDI- CPO corrected to 7.5. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some minor chipping of paint on the pool floor. Does not present hazard at time of inspection. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. Observed weir not tightly secured. -CDI- CPO repaired. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool furniture <6 ft. from pool edge. Maintain 6 ft. clearance around the pool in all locations. -CDI- CPO removed items. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
300-29x chlorinator installed without flow meter. For NSF approval, install flow meter on inlet line to chlorinator. Original construction. If ever replaced, ensure repaired per NSF standard. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms >120 F. Maintain at 110 F or below. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib in restrooms. Original construction. Provide hose bib with backflow prevention device. |